Aller au contenu principal

Sample Data

To try the module without typing a lot of setup first, the application installs sample data for a repair shop that services battery chargers, inverters, solar inverters and home appliances. It is installed when the application starts in a development or test environment, and never in production: a production installation sets up its own service stages, tasks and devices.

Nothing is installed twice. When the application starts again, an entry that is already there is left alone and an entry that is missing is added back. The workflow is the exception: it is installed only when no service stage exists yet, so a workflow you built yourself is never mixed with the sample one.

Sample data in Arabic​

The same sample data is also available in formal Arabic, in the folder Setup/ServiceManagement/ar of the application. The codes are the same as in the English files (RECEIVED, CHG-005-0001 and so on); only the descriptions are translated.

To install the Arabic version, set the environment variable SERVICE_MANAGEMENT_SEED_LANGUAGE to ar before the application starts. Without it, the English version is installed. Only one language is installed into a database: because an entry whose code already exists is left alone, starting again in another language does not translate what is already there. To switch language, start from a database that has no service management setup yet.

The workflow​

The sample workflow follows the steps of the shop: receive, inspect, repair, or cancel when the parts are not available or the cost is too high for the customer.

RECEIVED
└─ INSPECTION
├─ REPAIR
│ ├─ COMPLETED
│ └─ CANCELED_REPAIR (needs a reason)
└─ CANCELED_INSPECTION (needs a reason)
StageMeaningWhat it forbids
RECEIVEDThe device is in the shop and has not been inspected. Every order starts here.Invoicing.
INSPECTIONThe fault is diagnosed and the customer is given the price.Invoicing.
REPAIRThe customer accepted the price and the work is in progress.Deleting, invoicing.
COMPLETEDRepaired, tested and ready to collect.Changing, canceling lines, deleting.
CANCELED_INSPECTIONCanceled after inspection.Changing, canceling lines, deleting.
CANCELED_REPAIRCanceled during repair.Changing, canceling lines, deleting.

Moving to a canceled stage needs a reason. The sample reason codes are:

Reason codeMeaning
PARTS_UNAVAILABLERequired parts are not available.
COST_TOO_HIGHThe repair cost is too high for the customer.
BEYOND_REPAIRThe device cannot be repaired.
CUSTOMER_WITHDREWThe customer withdrew the order.

An order can also be moved back (for example from COMPLETED to REPAIR when the customer returns with the same fault), because every stage allows transfers.

Devices​

The devices are examples to take in on an order. They are in five groups:

GroupExamples
BATTERY_CHARGERS5 A, 10 A and 30 A chargers (CHG-005-0001, CHG-010-0001, CHG-030-0001, ...).
HEAVY_CHARGERS200 A chargers for large battery banks (CHG-200-0001, CHG-200-0002).
INVERTERS1 kW, 3 kVA and 5 kVA inverters (INV-1000-0001, ...).
SOLAR_INVERTERSHybrid solar inverters and an MPPT charge controller (SOL-3000-0001, ...).
HOME_APPLIANCESA washing machine, a refrigerator, a microwave oven and a fan (APP-WASH-0001, ...).

The amperage or power is part of the device code and description, so a charger is found by what it is. No device is linked to an inventory item.

The repair vocabulary​

ListWhat is installed
Service tasksDiagnose, clean and service, replace a component, repair the board, replace a fuse or the fan, rewire, rewind a transformer, reconfigure, load test.
Repair conditionsGood, worn, cracked case, water damage, burnt, opened by someone else.
Repair resolutionsRepaired, part replaced, adjusted, no fault found, beyond repair, canceled by the customer.
Repair stagesReceived, diagnosing, waiting for parts, in repair, testing, finished, unrepairable.
Symptom areasPower, charging, output, display and controls, solar, cooling and noise, home appliance, each with its codes (for example Does not charge the battery).
Diagnosis areasPower stage, capacitors, control board, wiring and connections, cooling, protection, battery, appliance parts, each with its codes (for example Blown MOSFETs or transistors).

What the sample data does not include​

  • Customers and items. Take customers from Accounts receivable and items from Inventory. For walk-in customers use one customer account.
  • The order number sequence. Set it under Service management > Setup > Parameters (Service orders).
  • Orders. Create them yourself on the Service orders page; the data above is what you choose from.

Where the data comes from​